Basic Specifications
Signal Detection Limit:
The sensitivity of the QuantaMaster™ UV VIS fluorescence spectrometer was assessed by testing fluorescein solution in 0.1 N NaOH. Equipped with sensitivity enhanced optics, the fluorescein spectrum is clearly detectable in the attomolar range under the experimental conditions.

Signal to Noise Ratio: 10,000:1 or better
Data Acquisition Rate: 1000 points/sec. to 1 point/100 sec.
Wavelength Range: 180 nm to 24 microns, continuously tunable (useful illumination wavelength range dependent on grating and lamp; useful detection wavelength range dependent on grating and photomultiplier tube)
Bandwidth: 0 to 25 nm, continuously variable
Detection Range: 185 to 680 nm with standard 1527 PMT (extended range to Near IR available)
High Voltage Range: -200 to -1,100 VDC
Resolution: 0.2 nm
Accuracy: +/- 0.5 nm
Excitation Source
- High efficiency continuous illumination system:
- 75W xenon lamp provides virtual point source of broadband illumination
- Can accommodate 100W Mercury, 100W Tungsten-Halogen or 150W Xenon lamps
- IR filter provided in the excitation path to prevent thermal damage to system
- Wavelength range of illumination (with the IR filter in place) 200 to 650
nm
Power
supply:
- Line voltage regulation 0.1% current variation for 5 volt line change
- Load regulation 0.1% current variation for 50% change in load impedance
- Stability after warm-up 0.2%
Igniter:
- High voltage (30 KV) start pulse
- Highly shielded starter to prevent RF interference to computer and
peripherals
- Continuous
excitation correction monitors excitation beam
- Automatically corrects for short- or long-term fluctuations in intensity
- Located in sample compartment
Back to top.
Excitation
Control
- QuadraScopic™ monochromator:
- Two entrance and two exit ports for additional excitation sources and/or
detectors
- Auto-calibrated and computer-controlled for scanning and positioning
- Continuously adjustable spectral bandwidth from 0 to 25 nm via micrometer slits
- Optional computer-controlled (patent pending) slits or micrometer slits
- Throughput 60% at 300 nm
- Stray light <0.02% two bandwidths from 365 nm Hg line
- Czerny-Turner optical configuration
- f/4 aperture ratio 200 mm focal length
- Reciprocal linear dispersion (with standard 1,200 l/mm grating) 4 nm/mm
- Accuracy ±0.5 nm
- Resolution 0.2 nm
Other
monochromator options:
- Dual gratings to efficiently cover an extended wavelength range
- Double monochromators for lower stray light
- (useful for highly scattering samples such as suspensions or solids)
Grating:
- Standard ruled 1,200 l/mm blazed at 300 nm
- Optional holographic gratings available to cover the entire wavelength
range from 180 nm to 2,000 nm
Back to top.
QuadraCentric™ sample compartment:
- Four ports to accommodate various light sources and detectors
- Configurable in L-, T- or X-formats
- Quartz optics for optimum sample illumination and emission signal collection
- Roomy compartment permits easy access and accommodates various options
- Thermostatable 10 x 10 mm cuvette holder (requires external water bath, not included)
- One 10 x 10 mm quartz cuvette included
- Variable speed sample stirrer
- Lid-activated emission shutter to protect sensitive detectors
- Excitation and emission filter holders accommodate 2 in. square or 1 in. diameter round filters
- Provision for injection into sample
- Gas purgeable compartment
Back to top.
Emission
Control
- QuadraScopic™ monochromator, same as above
- Grating: Standard ruled 1,200 l/mm blazed at 400 nm
- Optional holographic gratings available to cover the entire wavelength
range from 180 nm to 2,000 nm
Back to top.
Detector
- Photomultiplier tube detector with wavelength range from 185 to 680 nm
- Extended wavelength range option to 900 nm available
- Analog or photon counting detection options, directly selectable on the photomultiplier housing.
- Analog for high signal levels or photon counting for low signal levels
- High voltage range 200 to 1,100 VDC, manually adjustable
- LCD display on detector indicates actual cathode voltage
- Temperature coefficient ±0.01% max. (+5 to 40 deg. C)
- Drift ±0.03%/hr. max. (after 15-minute warm-up)
Photon counting mode:
- Maximum count rate 3.8 MHz
- Pulse pair resolution 265 ns
- Rise time 20 ns
- Fall time 100 ns
- Pulse width 220 ns
Analog mode:
- Inherent noise 50 pA p-p typically (0.05 millisecond time constant)
- Offset correction ±50 nA.
- Gain settings 1, 0.1, 0.01, 0.001 x mA equals 1 volt
- Time constant settings 0.05, 0.5, 50 or 500 milliseconds
- LCD display on detector can be switched to display analog signal level directly
- Optional
PMT available for detection between 700 to 900 nm
- Optional cooled PMT housing available for IR detection noise reduction
Back to top.
Software and Electronics
FeliX32™ Advanced Fluorescence Analysis Software Package included a32-bit fluorescence analysis software developed specifically for
fluorescence by PTI. Very easy to use Windows-based interface. Data exportable in many formats for use in other applications.
Back to top.
Data Acquisition Characteristics
Signal to noise ratio of water Raman band 10,000:1
Back to top.
Optional
- Optional special light sources such as lasers for specialized applications available
- Data rate 1000 points per seconds to 1 point per 200 seconds.
Back to top.
Other
CE approved