QuantaMaster™ 30 Buyers Guide
Each of PTI's diverse and versatile fluorometer systems is designed with particular user needs in mind. The QuantaMaster™ 30 is a bench-top fluorometer that utilizes a pulsed excitation source. Primarily, the QuantaMaster™ 30 is designed for the user who needs the capability to measure both phosphorescence decays as well as to make steady state fluorescence and phosphorescence measurements. The instrument excells in very rapid measurement of phosphorescence decays using the single shot transient digitizer technique. The QuantaMaster™ 30 is the most sensitive fluorescence system using a pulsed light source however if you ONLY require intensity based measurements PTI's QuantaMaster™ 40 is recommended.
You would choose the QuantaMaster™ 30 if your needs were:
 |
To Measure Phosphorescence Decays
One can measure phosphorescence decays as short as 1 microsecond (with deconvolusion) to as long as seconds. The instrument digitizes decay data from each lamp shot, so the acquisition is very rapid. Even with extensive averaging of hundreds of lamp shots, the decay curve can be acquired in less then a second. |
 |
For Great Sensitivity
PTI offers the most sensitive fluorimeter system that uses a pulsed light source for excitation. Nevertheless it is not as sensitive as our QuantaMaster™ 40 fluorescence system, which uses a continuous light source – but as we have said before if you need to measure phosphorescence decays you don’t have a choice. Don’t despair – you can make your QuantaMaster™ 30 into the most sensitive fluorometer on the planet by simply adding the Q-5H system enhancement. This option adds the continuous excitation source to your system. |
 |
For Ultimate in Versatility – Obsolescence Proof
The open architecture design allows for the ultimate in flexibility. You can add various excitation sources – including lasers and LED’s, you can expand the system to measure fluorescence lifetimes, polarization, temperature ramping – in fact you can add virtually anything that you need for fluorescence and phosphorescence type measurements. While everything wears out - the QuantaMaster™ 30 can be upgraded and updated. |
| |
To measure LRET or make other lanthanides measurements
 |
The QuantaMaster™ 30 system
equipped with a single shot transient digitizer detection is invaluable in boosting the
detection sensitivity of otherwise almost
undetectable europium emission obscured
by fluorescence (trace at delay = 0) from
organic ligand. By integrating the decay 200 microseconds away from the
excitation pulse, a clean spectrum of
europium ion is observed (trace at delay =
200 μs ), while the impurity fluorescence is
completely suppressed. |
|
If you are looking for a less expensive, simpler or easier to use luminescence system, we invite you to consider the compact bench-top luminescence instruments offered by our sister company Optical Building Blocks Corporation (OBB). OBB provides simple, affordable, integrated bench-top systems for steady state and time-resolved luminescence research. For more information visit www.obb1.com |