Steady State Enhancement Q-5G for Felix32 QM-3 Systems |
|
The ultimate in Sensitivity! |
The Q-5 Steady State Enhancement includes a high intensity "Green" (high efficiency low consumption) continuous xenon source for excitation added to the second entrance port of the excitation monochromator for increased S:N of 10,000:1, detection limit of 460 attomolars of fluorescine. A high sensitivity PMT detector and flipping mirror are also included. For more information on Steady State systems from PTI check out our QuantaMaster™ 40.
Download Specifications (98 KB PDF) |
|
 |
|
|
|
Steady State Enhancement Q-5H |
|
The ultimate in Sensitivity! |
The Q-5H Steady State Enhancement includes a continuous high intensity xenon source for excitation added to the second entrance port of the excitation monochromator for increased S:N of 10,000:1, detection limit of 460 attomolars of fluorescine. The QuantaMaster™ 30 multi mode detector will allow for this mode of operation. For more information on Steady State systems from PTI check out our QuantaMaster™ 40.
Download Specifications (98 KB PDF) |
|
 |
|
|
|
Tunable Second Emission Detection Channel Q-7P for Felix 32 QM-3 Systems |
|
|
The Q-7P Second Emission Channel add-on for pulsed xenon illumination systmes includes a second computer controlled, autocalibrated QuadraScopic™ monochromator, a gated PMT detector, additional optics for the second emission channel of the sample compartment as well as a lid activated shutter.
Download Specifications (97 KB PDF) |
|
 |
|
|
|
Tunable Second Emission Detection Channel Q-730 |
|
|
The Q-730 Second Emission Channel add-on for QuantaMaster™ systems includes a second computer controlled, autocalibrated QuadraScopic™ monochromator, new multi-mode PMT detector, additional optics for the second emission channel of the sample compartment as well as a lid activated shutter.
Download Specifications (97 KB PDF) |
|
 |
|
|
|
Fluorescence Microscopy Enhancement Q-9A |
|
Allows emission wavelength selection when coupled to a microscope! |
The Q-9a Fluorescence Microscopy add-on for QuantaMaster™ systems includes a liquid light guide to couple the excitation source to a microscope and a excitation flipping mirror. For detection, another liquid light guide is mounted to the C-adapter of the microscope and transmits the emission signal to the second entrance port of the emission monochromator of the system. (C mount and adaptor for microscope required but not included)
Download Specifications (126 KB PDF) |
|
 |
|
|
|
Laser Lifetime Enhancement Q-11A |
|
235–1000 nm wavelength range! |
The Q-11a Laser Lifetime add-on for QuantaMaster™ systems includes a nitrogen pumped dye laser source to provide the excitation illumination, coupling optics, a stroboscopic detector and flipping mirror. For more information on Lifetime systems from PTI check out our LaserStrobe™.
Download Specifications (98 KB PDF) |
|
 |
|
|
|
Lifetime Enhancement Q-25 |
|
Lifetimes down to 100 picoseconds! |
The Q-25 Lifetime add-on for QuantaMaster™ systems uses a LED light source for excitation. Included are required optics and adaptors, strobe detector and a flipping mirror for the emission monochromator. LED sources are available but not included. For more information on Lifetime systems from PTI check out our TimeMaster™ 20.
Download Specifications (97 KB PDF)
View LEDs |
|
 |
|
TCSPC LED Lifetime Enhancement PM-1 for Felix 32 QM-3 Systems |
|
Lifetimes down to 40 picoseconds! |
The PM-1 TCSPC Lifetime add-on for QuantaMaster™ systems uses a LED light source for excitation. Included are required optics and adaptors, TCSPC detector, TCSPC board and a flipping mirror for the emission monochromator. LED sources are available but not included. For more information on TCSPC Lifetime systems from PTI check out our PicoMaster™1. |
|
 |
|
|
|
TCSPC ps Laser Diode Lifetime Enhancement PM-2 for Felix 32 QM-3 Systems |
|
Lifetimes < 10 picoseconds! |
The PM-2 TCSPC Lifetime add-on for QuantaMaster™ systems uses a picosecond Laser Diode light source for excitation. Included are required optics and adaptors, TCSPC detector, TCSPC board and a flipping mirror for the emission monochromator. LD sources are available but not included. For more information on TCSPC Lifetime systems from PTI check out our PicoMaster™ 2. |
|
 |
|
|
|
TCSPC LED Lifetime Enhancement PM-3 |
|
Lifetimes down to 40 picoseconds! |
The PM-3 TCSPC Lifetime add-on for QuantaMaster™ systems uses a LED light source for excitation. Included are required optics and adaptors, TCSPC detector, TCSPC board and a flipping mirror for the emission monochromator. LED sources are available but not included. For more information on TCSPC Lifetime systems from PTI check out our PicoMaster™1. |
|
 |
|
|
|
TCSPC ps Laser Diode Lifetime Enhancement PM-4 |
|
Lifetimes < 10 picoseconds! |
The PM-4 TCSPC Lifetime add-on for QuantaMaster™ systems uses a picosecond Laser Diode light source for excitation. Included are required optics and adaptors, TCSPC detector, TCSPC board and a flipping mirror for the emission monochromator. LD sources are available but not included. For more information on TCSPC Lifetime systems from PTI check out our PicoMaster™ 2. |
|
 |
|
|