Stopped Flow Accessory
The stopped flow accessory is used to rapidly mix small volumes of two (or more) different chemicals in a cuvette, quickly stop the flow of chemicals to the cuvette and monitor the resulting chemical reaction via optical means.
Download Flyer (174 KB PDF) |
 |
|
Four-position Sample Holder
The muli-position Peltier, featuring a four-position turret and magnetic stirring can accommodate standard cuvettes or microcuvettes. The automated sample holder has a controllable temperature range of -20°C to 105°C. |
 |
|
Powdered Sample Holder
The powdered sample holder head easily adapts to the solid sample base with one thumbscrew adjustment. The sample head can be disassembled for easy sample loading and cleaning.
Download Flyer (146 KB PDF) |
|
|
Front Face Solid Sample Holder
The front face solid sample holder, capable of both linear and rotational travel, was designed for the measurements of solid compounds, microscope slides, or films. The solid sample holder head mounts onto a base that can be removed easily to substitute a powder sample holder head.
Download Flyer (146 KB PDF) |
 |
|
Titrators
Titrations are performed to measure a number of biochemical and physical parameters, including binding constants, stoichiometry and kinetics. PTI offers fully automated titration solutions that are integrated into the software. Parameters such as mixing, volume, speed, and calibration are dictated in the software and can be adapted to your needs. |
|
Integrating Sphere
Redesigned for enhanced measurement of quantum yields of solids, films, and powders. We use a 6 inch diameter sphere and attach it directly to the sample chamber on the port opposite the excitation channel. This design minimizes the effect of the excitation, emission, and sampling ports on the accuracy of the measurement. |
 |
|
Single Cuvette Peltier
The Peltier provides unmatched temperature stability and accuracy over the controllable temperature range of -20°C to 105°C. |
 |
|
Muscle Strip
The muscle strip is inserted into a standard 1 cm cuvette, and can be used with any cuvette-based fluorescence system having a standard single cuvette holder complete with tension transducer and transducer mounting bracket with micrometer position adjustment. |
|
Polarizers
PTI offers a wide variety of polarizers ranging from manual sheet polarizers (view graph) to automated large aperture Glan Thompson polarizers (view graph). |
 |
|
Filters |
 |
|
Cold Finger Dewar
The cold finger dewar is designed to be used with liquid nitrogen as coolant (77 K). It can also be used with organic solvent slushes at discrete temperatures above 77 K.
Download Flyer (126 KB PDF) |
 |
|
Remote Sensing Accessory
The remote sensing accessory allows in vitro or in vivo measurement by means of a quartz bifurcated fiber bundle or Liquid Light Guide. |
|
Selections of Long-pass Filters
Long-pass filter sets provide spectral discrimination for the emission channel and prevent the excitation light from being detected by the PMT. Filters should be selected so they cut off unwanted wavelengths, such the second order. The filters should be used with a filter holder (2 filter holders included with instrument).
The longpass filter set includes 1 inch round filters with cut-off wavelengths of 345, 400, 445, and 515 nm
|
 |
|
Bandpass Filters
10 nm bandpass interference filters are available individually or as a set. The peak transmittance wavelengths are 280, 289, 297, 308, 334 nm and from 340 nm to 650 nm at 10 nm increments. The filters should be used with a filter holder (2 filter holders included with instrument). The bandpass filters are especially recommended for:
- FRET experiments when looking at donor fluorescence
- Samples which exhibit fluorescent tautomeric forms
- Excimer and exciplex systems, when looking at the monomer emission band
- Molecules, which undergo excited state proton transfer (ESPT) or intramolecular charge transfer (ICT, TICT) and exhibit dual fluorescence bands
- Experiments, which require elimination of unwanted emission at longer wavelengths
|
|
Neutral Density Filters
Neutral density filter set. The neutral density filter set consists of six 1inch round filters with approximate optical densities of 0.1, 0.3, 0.5, 1.0, 2.0 and 3.0 suitable for a spectral range of 300–2000 nm. The filters should be used with a filter holder (2 filter holders included with instrument). The neutral density filters are used to decrease the signal intensity without changing the width of the emission slit. |
|
Semimicro Cuvette
The semi-microcuvette cuvette and insert lets the end user save money and time by using smaller volumes of samples while maintaining the correct optical height. |