Phosphorescence Enhancement Q-4 |
|
Measure lifetimes greater than 400 nanoseconds! |
The Q-4 Phosphorescence Enhancement includes a pulsed xenon light source and a gated PMT detector as well as excitation and emission flipping mirrors. For more information on Phosphorescence systems from PTI check out our QuantaMaster™ 30.
Download Specifications (98 KB PDF) |
|
 |
|
|
|
Tunable Second Emission Detection Channel Q-7 |
|
|
The Q-7 Second Emission Channel add-on for QuantaMaster™ systems includes a second detector of the same type as the primary emission channel and a second channel quartz optics for the sample compartment is also included.
Download Specifications (97 KB PDF) |
|
 |
|
|
|
Second Emission Channel Enhancement Q-7b |
|
|
The Q-7 b add-on for QuantaMaster™ systems includes a high sensitivity PMT detector coupled directly to the sample compartment, wavelength selection by means of filters. It can operate in both analog and digital (photon counting) modes. Additional optics for the sample compartment and a lid activated shutter are also included.
Download Specifications (90 KB PDF) |
|
 |
|
|
|
Fluorescence Microscopy Enhancement Q-8a |
|
For the most sensitivity
when coupled to a microscope! |
The Q-8a Fluorescence Microscopy add-on for QuantaMaster™ systems includes a liquid light guide to couple the excitation source of an existing system to a microscope, a excitation flipping mirror and a complete photometer using high sensitivity PMT detection(C port and adaptor for microscope required but not included).
Download Specifications (123 KB PDF) |
|
 |
|
|
|
Fluorescence Microscopy Enhancement Q-9a |
|
Allows emission wavelength selection
when coupled to a microscope! |
The Q-9a Fluorescence Microscopy add-on for QuantaMaster™ systems includes a liquid light guide to couple the excitation source to a microscope and a excitation flipping mirror. For detection, another liquid light guide is mounted to the C-adapter of the microscope and transmits the emission signal to the second entrance port of the emission monochromator of the system. (C mount and adaptor for microscope required but not included)
Download Specifications (126 KB PDF) |
|
 |
|
|
|
Fluorescence Microscopy Enhancement Q-9b |
|
For selection of emission area on microscope |
The Q-9b Fluorescence Microscopy add-on for QuantaMaster™ systems includes a liquid light guide to couple the excitation source to a microscope, for detection, another liquid light guide is mounted to the exit port of a PTI photometer that is mounted on the C-port of the microscope. The emission signal is transmitted back to the second entrance port of the emission monochromator of the system. Flipping mirrors are used to select whether the light is directed from the sample compartment or the microscope. (C mount and adaptor for microscope required but not included)
Download Specifications (97 KB PDF) |
|
 |
|
|
|
Laser Lifetime Enhancement Q-11a |
|
Add fluorescence lifetime capability from
331–1000 nm (235 to 1000 nm optional) |
The Q-11a Laser Lifetime add-on for QuantaMaster™ systems includes a nitrogen pumped dye laser source to provide the excitation illumination, coupling optics, a stroboscopic detector and flipping mirror. For more information on Lifetime systems from PTI check out our LaserStrobe™.
Download Specifications (98 KB PDF) |
|
 |
|
|
|
Lifetime Enhancement Q-25 |
|
Lifetimes down to 100 picoseconds! |
The Q-25 Lifetime add-on for QuantaMaster™ systems uses a LED light source for excitation. Included are required optics and adaptors, strobe detector and a flipping mirror for the emission monochromator. LED sources are available but not included. For more information on Lifetime systems from PTI check out our TimeMaster™ 20.
Download Specifications (97 KB PDF)
View LEDs |
|
 |
|
|
|
NIR Enhancement Q-73 |
|
Unmatched NIR capability from 500 to 1700 nm! |
The Q-73 NIR add-on for QuantaMaster™ systems uses the existing high intensity 75 watt xenon light source, excitation scanning monochromator and sample compartment but substitutes a high sensitivity TE-cooled InGaAs detector, electronics, lock-in amplifier and chopper for noise suppression, and includes an additional emission 600 groove grating blazed at 1.2 microns. For more information on NIR systems from PTI check out our QuantaMaster™ 50 .
Download Specifications (96 KB PDF) |
|
 |
|
|
|
Extended NIR Enhancement Q-73b |
|
Unmatched NIR capability from 900 to 2200 nm! |
The Q-73b NIR add-on for QuantaMaster™ systems is the same as the Q-73 but detection is extended out to 2.2 microns. For more information on NIR systems from PTI check out our QuantaMaster™ 50.
Download Specifications (96 KB PDF) |
|
 |
|
|